Welcome to the Chelsea Technologies Group On-Line Shopping SiteChelsea Technologies GroupChelsea Technologies GroupLink to full Chelsea Technologies Group website

Chelsea Technologies Group is the world's leading designer and manufacturer of in-situ fluorimeters and is pleased to launch its new range of low cost digital fluorimeters, which can now be purchased, online.

    • Product UviLux Fluorometer successfully added to compare list
    • Product UviLux Fluorometer successfully added to compare list
    • Product UviLux Fluorometer successfully added to compare list
    • Product UviLux Fluorometer successfully added to compare list
    • Product UviLux Fluorometer successfully added to compare list
    • Product UviLux Fluorometer successfully added to compare list

Miniature, low cost in-situ UV fluorimeter to to monitor in real-time refined polyaromatic hydrocarbons, crude hydrocarbons, CDOM and Tryptophan

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

UviLux Fluorometer

Be the first to review this product

Availability: 14 Days.

£ 5,000.00

Quick Overview

Miniature, low cost in-situ UV fluorometer to monitor in real time the concentration of refined hydrocarbons (365nm) or crude hydrocarbons (450nm), Coloured Dissolved Organic Matter (CDOM) and Tryptophan.

* Required Fields

£ 5,000.00
Add Items to Cart Add to Cart


The UviLux is an innovative, sensitive, low cost, digital in-situ UV fluorometer that offers the user significantly increased functionality when compared to existing UV fluorometers. Variants of the UviLux provide real-time monitoring of the concentration of refined polyaromatic hydrocarbons (365nm), crude hydrocarbons (450nm), Coloured Dissolved Organic Matter (CDOM) and Tryptophan, a surrogate marker for Biological Oxygen Demand (BOD) and bacterial contamination in waste, recycled and natural water supplies. The UviLux can be deployed in a wide range of coastal, oceanographic and fresh water applications. The UviLux has an acetal resin housing suitable for deploying independently as well as from submersible vehicles, moored or profiling systems. This robust, compact, lightweight fluorometer has very low power consumption, is easy to use and gives accurate and repeatable measurements.

The fluorometer utilizes a novel UV LED light source and a miniature 8-stage photomultiplier coupled to a low noise preamp, which combined with phase sensitive detection, provides highly sensitive measurement capabilities. The sophisticated electronic signal processing, combined with cowl design principles employed in our UV AQUAtracka, enables the UviLux to operate successfully in high levels of ambient light. Because of this, there is no requirement to pump sample through a dark measurement chamber, thus obviating the need for water flow corrections or the cost, inconvenience and power drain of a pump. The UviLux can be supplied with either recessed or flush windows depending upon the required application. For deck & laboratory use, a flow through manifold is also available. Ease of use and installation is further enhanced by the provision of galvanic isolation between the power and signal 0V rails, thereby avoiding the possibility of  'ground loops'. The highly efficient, proprietary, d.c. converter can also handle an unusually wide supply voltage range of 9V to 36V without significant change to the power consumption of 1.3W.

Two signals can be obtained from the standard UviLux: the first is a digital RS232 output in engineering units, the second a 0V to 5V volt calibrated analogue output derived from the digital signal. Single RS422 and SDI-12 outputs are also available as options. This flexibility makes the UviLux suitable for integrating into many different systems and platforms.

A Windows based Graphical User Interface (GUI) is provided that allows the user to both plot and record time stamped data when operating the UviLux directly from a PC and gives control over a many instrument parameters, including: sampling rate, detector sensitivity, and calibration factors. Although small and low cost, the UviLux fluorometer maintains the performance standards and build quality previously maintained by the CTG’s range of in-situ fluorometers.

Performance

Parameter
Polyaromatic Hydrocarbon
CDOM
Tryptophan
Excitation wavelength:
255nm
255nm
280nm
Emission wavelength:
365nm
450nm
365nm
Calibrated range:
0.02 to 200 μg/L Carbazole
0.02 to 150 μg/L Perylene
0.03 to 500 ug/L Tryptophan
Limit of detection:
<0.02μg/L
<0.02μg/L
<0.3μg/L

 
Mechanical
Size:                  
70mm dia x 149mm
Weight in air:
0.8 kg
Weight in water:
0.15 kg
Pressure housing:
Acetal C
Depth rating:
600 metres
Connector:
Subcon MCBH6M
 
Environmental                                                
Operating Temperature:
-2ºC to +40ºC
Storage Temperature:    
-40ºC to +70ºC
 
Electrical
Input voltage:
9 to 36Vdc
Data output:
Digital RS232 and analogue 0 to 5Vdc (RS422 and SDI-12 options)
Power requirements:      
<1Watt @ 12 volt
 

Delivery Package  
The standard UviLux fluorometer is supplied with transit case, handbook and Windows based Graphical User Interface (GUI).

Accessories:  User to specify cables and other accessories.

 
 

 

 

 

 

Applications

· In-situ polyaromatic hydrocarbon detection
· Crude and refined oil spill monitoring
· Hydrocarbon detection around drilling rigs
· Sub-sea pipeline leak detection
· Airport apron pollution runoff
· Coastal pollution monitoring
· Biogeochemical oceanography
· Environmental impact assessment
· Biomass indicator studies (CDOM/Tryptophan)
· Waste/recycled water quality monitoring
· Effluent detection
· Towed, moored or ROV deployments
 

Features:

· Small, low cost in-sit fluorometer 
· Range of wavelengths available
· Digital output in engineering units
· Additional analogue output as standard
· User selectable sampling rate, 0.1Hz - 3Hz
· Low power consumption
· High rejection of ambient daylight
· Low noise, high sensitivity
· Low turbidity breakthrough
· User adjustable dynamic range
· RS232 & analogue output (or RS422 option)
· Acetal C housing

The standard UviLux Fluorometer is supplied with transit case, handbook and Windows based Graphical User Interface (GUI). There is now a range of accessories available to compliment the UviLux Fluorometer . You will need to decide on cable type, length and cable termination. You will also need to give consideration to how you wish to interface the fluorometer to either a laptop, PDA or your own system.

To help you decide which accessories you may need for the UviLux fluorometers, please check out the accessories on main website


If you need advice regarding which accessories you may need, please telephone Ellen Keegan on +44(0)20 8481 9019.  Email: ekeegan@chelsea.co.uk.

© Copyright 2012 - Chelsea Group Technologies Ltd, UK - All Rights Reserved
Ecommerce Web Design & Search Engine Optimisation by Creare
w3cvcss